RuiXingHengFang Network(Shenzhen)Co.,Ltd,

Innovation shapes the future

Manufacturer from China
Active Member
3 Years
Home / Products / Ultrasonic Water Meter /

LORAWAN Valve Controlled Ultrasonic Water Meter Micro Power Consumption RHF1S214C

Contact Now
RuiXingHengFang Network(Shenzhen)Co.,Ltd,
City:shenzhen
Country/Region:china
Contact Person:Leo Xie
Contact Now

LORAWAN Valve Controlled Ultrasonic Water Meter Micro Power Consumption RHF1S214C

Ask Latest Price
Video Channel
Brand Name :RisingHF
Model Number :RHF1S214C
Certification :China "JJG 162-2009 Cold Water Meter Verification" standard
Place of Origin :china
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Overview

  • LORAWAN wireless valve control ultrasonic water meter is using ultrasonic testing technology of new intelligent all electronic valve control meter. The meter set measurement, integration, display, valve control, LORAWAN wireless communication of the Internet of Things water meter, using micro power consumption technology, with low initial flow, high range ratio, small volume, good stability, strong anti-interference ability and other characteristics.
  • The use of ultrasonic flow measurement technology, can achieve multi-angle installation, instrument measurement is not affected, at the same time to minimize the pipeline pressure loss.l
  • Through LORAWAN wireless remote control switch valve, in order to realize the remote control of the water by the user.
  • Specially used for household metering in residential areas.
  • LORAWAN wireless valve control ultrasonic water meter can send data through the Internet platform.
  • The factory verification is based on the National Metrological verification Regulation of the People's Republic of China "JJG 162-2009 Cold Water Meter Verification" standard.

Technical parameters

Table 1-1 Technical parameter table

parameter performance
Nominal diameter (mm) DN15~DN20
Q3/Q1 250
Pressure loss class Δp40
measured medium Water, homogeneous liquid, and fill the pipe under test
class of accuracy Level 2
Maximum allowable working pressure 1.0MPa
Working Environment 5℃~+55℃,≤100%RH
Class of temperature T30
Sensitivity level of upstream flow field U10
Sensitivity level of downstream flow field D5
Climatic and mechanical environment grades Class B
Electromagnetic compatibility level E1
Key Type Touch key
Display unit LCD 8 digit + prompt
Display Content Instantaneous flow (m³/h), cumulative flow (m³), screen detection, table address, cumulative working time (h), date (year/month/day), caliber, software version
Range of display Accumulated flow rate:0m³~+99999.999m³
Data communication Photoelectric interface Baud rate 2400bps, using CJ/T 188 based on the custom protocol
Wireless communication

lorawan uses a custom protocol based on CJ/T 188

The default communication is once a day

Working power supply Battery powered DC3.6V; Two ER26500 batteries
level of protection IP67/ IP68
Storage temperature -25℃~+55℃

Table 1-2 Flow parameter table

Nominal caliber Q3(m³/h) Q2(m³/h) Q1(m³/h) Q4(m³/h)
DN15 2.5 0.016 0.01 3.125
DN20 4.0 0.025 0.016 5

Overall dimensions

LORAWAN Valve Controlled Ultrasonic Water Meter Micro Power Consumption RHF1S214C

Nominal diameter (mm) DN15 DN20
The screw thread G¾B G1B
L(mm) 142 142
L1(mm) 165 195
H(mm) 98.2 98.2
W(mm) 102 102

Operation Instructions

  • Panel indicator

LORAWAN Valve Controlled Ultrasonic Water Meter Micro Power Consumption RHF1S214C

  • Operation instructions

Users can switch between the display buttons, view the instrument measurement data, cyclic display. As shown below:

LORAWAN Valve Controlled Ultrasonic Water Meter Micro Power Consumption RHF1S214C

◆Installation and Connection

1 Installation and connection requirements

◇ Strictly according to the professional design of the installation position, is strictly prohibited to move.

◇ The newly installed pipe must be cleaned of sand, silt and other sundries in the pipe before installing the table, so as not to cause the failure of the water meter.

◇ When installing a water meter, pay attention to the connection length of the water meter. If the distance between the pipes at both ends exceeds the connection length of the water meter, adjust the pipe distance to meet the connection length of the water meter and ensure that the pipes at both ends of the water meter are on the same axis.

◇ In order to ensure the measurement accuracy, the straight pipe section above 10D should be reserved before the table, and the straight pipe section above 5D should be reserved after the table, to avoid the interference of elbow, tee, cone and pump as far as possible (D is the pipe diameter). If the pipe in front of the table has a reduced diameter pipe, the straight pipe section in front of the table is more than 15D; When the pipe in front of the table has 90° elbow, the straight pipe section in front of the table is above 20D; When the pipe in front of the meter has a half-open valve, the straight pipe section in front of the meter is above 50D.

◇ The water meter should be protected from damage caused by impact or vibration of the environment around the installation site. The water meter should also be protected from excessive stress caused by pipes and fittings. If necessary, the water meter should be installed on the base or bracket.

◇ Extreme water temperature and temperature should be prevented from damaging the water meter and prevent the corrosion of the external environment from damaging the water meter.

◇ Measures should be taken to prevent adverse hydraulic conditions (cavitation, surge, water hammer).

◇ If the product is installed in the open air and submerged in water, it should be informed in advance

2 Installation position

◇Installed in the liquid upward (or oblique upward) flow of the vertical pipe, followed by the horizontal pipe, as far as possible to avoid the liquid down(or diagonal downward) flow pipe to prevent liquid discontent pipe.

◇The installation position should not be selected at the highest point of the pipeline direction to prevent the abnormal measurement caused by the accumulation of bubbles in the pipeline

LORAWAN Valve Controlled Ultrasonic Water Meter Micro Power Consumption RHF1S214C

3. Installation Method

◇ Cut off the water supply pipe installation meter to leave a place for installation, as shown in the figure:

LORAWAN Valve Controlled Ultrasonic Water Meter Micro Power Consumption RHF1S214C

◇Align the instrument with the pipe concentrically, connect the pipe blade with the thread of the instrument with a wrench, and tighten the instrument installation

LORAWAN Valve Controlled Ultrasonic Water Meter Micro Power Consumption RHF1S214C

Verification function

This instrument verification method follows JJG 162-2009 Cold Water Meter Verification RegulationØ

Trouble removal

◇ Cold water meter display :

Indicates that the battery is low. Replace the battery as soon as possible

◇ The cold water meter shows a negative number

Check whether the direction of water inlet and outlet are reversed. If not, please return to the original factory for solution.

◇ Data on the cold water table is abnormal or jumbled

①The installation position is incorrect. The installation position is at the lower water level

②The front and rear straight pipe section is too short, the bend is too large, and the diameter of the pipe before the meter is large

◇ Cold water meter has flow rate but no temperature

Do not dismantle without permission, return to the original factory.

Product accessories list

The serial number Name Unit The number of Note
1 Intelligent valve controlled water meter PCS 1
2 Product specification PCS 1
3 Warranty card of Quality Certificate PCS 1
4 Seal ring PCS 2
5 Hose screw PCS 2 optional
6 Union nut PCS 2 optional

Transportation and Storage

1. The water meter should be stored in the original package in an environment with an ambient temperature of 5℃ to 40℃ and no corrosive gases in the air.

2. When the water meter is stored on the shelf, the stacked height of the whole box shall not exceed 5 boxes.

Disclaimer of liability

1. This water meter is a fixed water meter (Class B) installed indoors for residential, commercial and light industrial (Class E1) use.

2. The Instruction manual of our company is without any express or implied warranty, and we have the right to change and revise this instruction manual without prior notice. All products are based on the actual products.

3. If the seal lead is damaged or incomplete, the company will not be liable; In addition, the Company does not assume any other relevant responsibilities other than the water meter (including but not limited to the liability for water metering disputes caused by the failure or error of the water meter).

Inquiry Cart 0